DAA1-LINE Single Phase EMI Filter (1A–10A) with Wire Leads
✔Rated Voltage:115VAC-250VAC
✔Rated Current:1A,3A,6A,10A
✔Certificate:cUL,CB,CE,ROHS
✔Support free samples
✔OEM/ODM support
✔Technical documentation
✔Manufacturer engineering review
Compact AC Power Line Noise Filter | 115/250VAC | 50/60Hz | Chassis-Mounted
TheDOREXS DAA1-LINE is a compact, single-phase AC power line EMI filter with wire-lead connections, designed to help reduce conducted electromagnetic interference at an equipment's power input. The DAA1 series offers 1A, 3A, 6A and 10A current ratings and a 115/250VAC rated-voltage specification. The wire-lead design allows integration into compatible equipment enclosures and power-entry assemblies.
Its circuit uses filtering elements to attenuate noise between line and neutral as well as noise coupled to the protective-earth path. Applications include electronic equipment, industrial control power supplies, purification equipment and low-current auxiliary circuits in machinery. Actual attenuation depends on the equipment, impedance, grounding and installation layout.
Looking for a filter for a new design or an EMC issue?Request a DAA1-LINE quotation or engineering review.
Key Features & Engineering Benefits
- Four rated-current options: 1A, 3A, 6A and 10A for different AC input loads.
- Wire-lead connections: suited to wired power-entry integration when compatible with the enclosure and assembly process.
- Compact metal enclosure: nickel-plated iron housing with mounting provision.
- Common-mode and differential-mode attenuation: the reference circuit includes coupled inductors and line-to-line/line-to-earth capacitive elements.
- Specified insulation and electrical testing: series data lists 1500VDC line-to-line and 2150VAC line-to-ground test voltages, plus insulation resistance above 50MΩ at 500VDC.
- Customization support: electrical and connection requirements can be reviewed by DOREXS engineers before production.
Technical Specifications
Parameter | DAA1 Series / DAA1-LINE Reference |
|---|---|
| Product designation | DAA1-LINE (wire-lead configuration) |
| Filter type | Single-phase AC power line EMI filter |
| Rated voltage | 115/250VAC |
| Rated current options | 1A, 3A, 6A, 10A |
| AC line frequency | 50/60Hz |
| Leakage current | <0.5mA |
| Test voltage, line-to-line | 1500VDC |
| Test voltage, line-to-ground | 2150VAC |
| Insulation resistance | >50MΩ at 500VDC |
| Temperature rise | <30°C |
| Climatic category | 25/085/21 |
| Housing material | Nickel-plated iron |
| Connection | Wire leads |
| Mounting | Chassis mounting |
| Compliance documentation | cUL, CE, CB and RoHS |
Available Current Ratings
DAA1 Series Reference | Rated Current | Leakage Current | Connection for This Page |
|---|---|---|---|
| DAA1-1A | 1A | <0.5mA | Wire-lead variant |
| DAA1-3A | 3A | <0.5mA | Wire-lead variant |
| DAA1-6A | 6A | <0.5mA | Wire-lead variant |
| DAA1-10A | 10A | <0.5mA | Wire-lead variant |
Mechanical Design & Wire-Lead Connection


The photographed DAA1-LINE version has a metal chassis enclosure with wire leads entering and leaving the filter body. This connection style is different from the DAA1-Insert configuration, which uses blade terminals.
The provided PDF contains a blade-terminal dimensional drawing, not a validated wire-lead mechanical drawing. Accordingly, wire length, conductor cross-section, lead exit positions and overall dimensions including leads are not stated as final specifications on this page. Please request the current DAA1-LINE drawing before designing mounting holes, cutouts or wiring harnesses.
Request the DAA1-LINE mechanical drawing.
Typical Filter Circuit & Noise Suppression

Reference DAA1 series circuit from supplied June 2023 datasheet; not a lead-color wiring diagram.
The typical DAA1-series circuit contains inductive and capacitive filtering elements on the line and neutral conductors, with a protective-earth connection used by the capacitive noise-suppression network. This arrangement can help attenuate both differential-mode noise (between line and neutral) and common-mode noise (with respect to the equipment ground).
The circuit shown is a reference electrical topology, not a wire-color pinout or an installation wiring diagram. Confirm the input, output and protective-earth markings on the exact product before connection.
Insertion Loss Performance
Actual results in an installed system can differ because of source and load impedances, earth bonding, enclosure structure, cable routing and noise-source characteristics. Request a variant-specific test report when a quantified attenuation target is required.
Approvals and Compliances

Typical Applications
Industrial Control & Power Supply Equipment
For compatible 115/250VAC input circuits in control panels, small power supplies and electronic control units, DAA1-LINE can be considered to help reduce conducted switching noise. Filter current, grounding and installation space should be checked against the equipment design.
Disinfection, Purification & Electronic Equipment
The DAA1 datasheet identifies disinfection and purification equipment among its application areas. The wire-lead version may suit internal AC input connections where its current rating and insulation specifications meet the equipment's design requirements.
Robotics & Machinery Auxiliary Power
Control electronics and low-current auxiliary supplies used in robotic or laser-processing equipment can generate or receive conducted EMI. DAA1-LINE may be evaluated at an appropriate AC input point; it should not be treated as a filter for the full mains power of a high-power machine without verifying the load.
General Electrical & Electronic Assemblies
Its compact metal enclosure and wire leads can support integration into other single-phase electronic systems where a qualified mains EMI filter is required. Suitability must be established through electrical safety review and, when applicable, system-level EMC testing.
Installation & EMI Filter Selection Guide
1. Confirm voltage and current. Check whether the AC system matches the documented 115/250VAC rating. Select 1A, 3A, 6A or 10A based on the true RMS input current, relevant transients, ambient temperature and applicable design margin.
2. Identify LINE, LOAD and protective earth. Follow the markings and confirmed wiring documentation for the exact unit. Do not assume conductor function solely from wire color.
3. Bond the enclosure correctly. Use the approved protective-earth connection and secure the filter chassis in accordance with the equipment safety design. Installation must be carried out by qualified personnel with power isolated.
4. Keep noisy and clean wiring separated. Route the unfiltered input and filtered output away from one another where practical. Short, well-managed connections and sound earthing help avoid high-frequency coupling around the filter.
5. Validate performance in the assembled equipment. Compare conducted-emission test results with and without the filter under representative operating conditions. A filter alone cannot guarantee that the finished device will pass an EMC standard.
For broader selection guidance, see How to Select an EMI FilterandSingle Phase EMI Filters.
OEM/ODM Customization & Manufacturer Support
DOREXS develops and manufactures EMI filtering products and supports equipment manufacturers, system integrators and industrial procurement teams with product selection and application evaluation.
For a DAA1-LINE project, the engineering team can review rated-current requirements, available space, wire-lead construction, electrical test requirements and other application constraints. Any proposed modification should be confirmed through an approved drawing and specification before an order is placed.
Share your project requirements: supply voltage, continuous input current, equipment type, lead length or connector requirements, installation space, estimated order quantity and any available conducted-emissions test results.
Technical Documents & Product Resources
- DAA1-LINE mechanical drawing: request the current wire-lead version before mechanical design release.
- DAA1 series datasheet: a series reference document is available; its termination/dimensional illustration depicts blade terminals and must not be used as the final DAA1-LINE wire-harness drawing.
- Insertion-loss or EMC documentation: ask DOREXS for test conditions and a report applicable to the required current rating and connection variant.
- Related variant:DAA1-Insert Single Phase EMI Filter.
- Engineering background:DAA1 EMI Power Filter Series.
Frequently Asked Questions
What is the DAA1-LINE EMI filter used for?
DAA1-LINE is a single-phase AC power line filter intended to help reduce conducted electromagnetic interference at suitable equipment power inputs. It is available in several current ratings and uses wire-lead connections for integration into compatible assemblies.
What is the difference between DAA1-LINE and DAA1-Insert?
Both belong to the DAA1 series, but the terminal configurations differ. DAA1-LINE has wire-lead connections, while DAA1-Insert uses blade-style terminals. Mechanical mounting, termination details and the final ordering code must be checked for the chosen version.
Which current ratings are available?
The DAA1 series datasheet lists 1A, 3A, 6A and 10A. Choose a model using the actual equipment current and relevant safety and thermal considerations rather than selecting solely from a nominal power rating.
What are the voltage and frequency ratings?
The supplied DAA1 datasheet states 115/250VAC and 50/60Hz. A previously published page also mentions 275VAC maximum operating voltage; that higher value has not been confirmed in the uploaded datasheet and is not used as the rated voltage here.
Is the leakage current below 0.5mA?
The datasheet lists leakage current below 0.5mA for each of its four DAA1 current ratings. As the provided table does not specify leakage measurement conditions, verify the applicable test voltage, frequency and end-equipment limit before final selection.
Will DAA1-LINE make my equipment pass EMC testing?
No single filter can guarantee system-level EMC compliance. Attenuation in the final equipment depends on the noise source, input and output wiring, cable layout, earthing and other components. Representative tests are recommended.
Can DOREXS supply a custom lead arrangement or mechanical drawing?
DOREXS indicates customization support for the DAA1 series. Share the required wire length, termination style, load current, drawings and projected quantity so the engineering team can confirm feasibility and an appropriate ordering specification.
Request a Quote or Engineering Assistance
Need a DAA1-LINE 1A, 3A, 6A or 10A wire-lead EMI filter for your equipment? Send us your input voltage, current rating, intended application, connection requirements and estimated order quantity. DOREXS can review the information and advise on suitable standard or custom options.
Comprehensive score